Chapter

Operating in SVĆCompatible Mode

5

5Ć30

There are no parameters for the RESET command. Before the scanner
executes the RESET command, the VME master processor writes these
parameters to the last 2 words of the selected channels’ general data area:

Byte

offset:

Parameter:

Description:

FBC

secondĆtoĆlast word in the selected

channel's general data area

Write the value 0080 (hex) to this word.

FBE

last word in the selected channel's

general data area

Write the value A0A0 (hex) to this word.

Your code for the RESET command needs to write the above words to byte
offsets FBC and FBE.

parameters

coding sequence