Chapter

Communicating with Remote I/O

4

4Ć11

Figure 4.7

BlockĆtransfer sequence - receiving data from a completed transfer

VME

master

processor

On the previous adapter scan, the scanner sent a block

transfer request. During this scan, the adapter returns the

response data to the scanner.

scanner

The application program must move the blockĆtransfer

data out of the general memory area and clear the

semaphore so other blockĆtransfers can be completed.

1771 I/O

chassis

adapter

#n

input

modules

output

modules

BT#n

BT

data

The scanner:
1.

tests and sets the semaphore

2.

places the blockĆtransfer data in the general data area

3.

places a completion code in the confirmation area

4.

provides the proper blockĆtransfer tag number

5.

generates a VME interrupt (optional)

BT

data

scanner's global RAM

BT#n

BT

data


scan n + 1