4-23

Programming Reference

P.015 Trim Gain Percentage

This parameter
specifies a
percentage of the
selected trim
reference entering
the speed regulator.

See figure 4.4.

Parameter Range:

-99.9 to +99.9% (1.0 = 1%)

Default Setting:

0.0

Parameter Type:

Tunable

Refer also to parameters: P.014 Trim Reference Source

Figure 4.4 – Draw and Trim Gain

See Appendix G for the complete block diagram.

P.016 Draw Gain Percentage

This parameter is
used to increase or
decrease the
selected speed
reference to the
speed regulator.

Parameter Range:

-99.9 to +99.9% (1.0 = 1%)

Default Setting:

0.0

Parameter Type:

Tunable

Refer also to parameters: N/A

This parameter allows multiple drive sections with a common line reference, but with
different values for draw gain, to run at different speeds depending on the percent
draw.

Draw Gain

Mul

Div

Trim Gain

Mul

Div

P.016

Draw

P.015

Trim

Selected

Speed Ref

To Speed Ref
Limit Block

100

100

+

+

+

Selected

Trim Ref

P.014