G-8

GV3000/SE 230 VAC Drive, Software Reference Version 6.04

Figure G.7 – Outer Control Loop Block Diagram

Network trim reference

(direct or broadcast

(P.064)),

RMI analog in,

or Preset Speed 8

(P.038)

x U.044

+

*

*

*

*

*

PI

Lim

Init

Rst

Kp (U.045)

Ki(U.046)

+/-4095

0

OCL feedback

* Available in netwoek read

registers

U.047

100

x

OCL enabled

(d1, r26, b2)

OCL L/L Ratio

(U.043)

Lead/Lag

Rst

Init

Input

OCL L/L Select

(U.041)

OCL L/L Low

Freq (U.042)

Netw OCL enable bit (d1, r32, b5), RMI

digital input, or TRUE if no option board

installed

Running

1

0

OCL fdbk select

(U.040)

Speed PI Output (torque ref)

Scaled TS Analog Input

(4095 @ 10 VDC)

G

Div

U.017

Mult

Spd ref S-curve block

output

ON

OFF

OCL Prop Trim

Enable (U.048)

OCL output

(to speed loop block diagram)

(From speed loop block diagram)

20 msec scan period