4-30

GV3000/SE 230 VAC Drive, Software Reference Version 6.04

For vector regulation, P.028 will correspond to U.017:

Actual Speed in RPM x P.028
U.017

= value displayed when SPEED monitor mode or
selected reference is selected.

P.027 Forward/Reverse Configuration

This parameter
specifies how the
motor responds to
forward or reverse
inputs from any
control source.

Parameter Range:

0 = Forward or reverse enabled from the selected

control source.

1 = Reverse disabled from the selected control

source.

2 = The state of the forward/reverse input is latched

when the motor is started.

Default Setting:

0

Parameter Type:

Tunable

Refer also to parameters: N/A

When P.027 is set to 0, the forward/reverse input allows forward or reverse rotation
of the motor.

When P.027 is set to 1, reverse rotation of the motor is prohibited and the
forward/reverse selection from the front panel or serial port is set to forward. Note
that reverse rotation is prohibited regardless of the polarity of the speed reference
input.

When P.027 is set to 2, the state of the forward/reverse input is latched when the
motor is started (RUNNING LED is on). Direction changes requested from any
control source after the motor is started are ignored. Note, however, that this
selection will not inhibit a motor direction change due to a change in the polarity of
the speed reference input.

In V/Hz regulation, setting H.016 (Sync Mode Direction) to any value but F may
cause the motor to operate in the reverse direction briefly regardless of the setting
in P.027.

P.028 Speed Display Scaling

This parameter
defines the scaling
value applied to the
manual reference,
the selected speed
reference, and the
output speed
displays.

Parameter Range:

10 to 9999

Default Setting:

Synchronous speed based on H.001 (assuming a
4-pole motor) (V/Hz)
U.017 (Vector)

Parameter Type:

Tunable

Refer also to parameters: U.017 Motor Top Speed

H.001 Motor Nameplate Base Frequency

Advertising