3-4

GV3000/SE 230 VAC Drive, Software Reference Version 6.04

Figure 3.3 – Example of a Program Mode Display

3.3

Drive Control

When the control source is the local keypad/display (REMOTE LED is off), the
keypad is used to control the drive. This means that the drive will respond to
START, RUN/JOG, and FORWARD/REVERSE commands only from the keypad.

The functions of the keypad keys are described in section 3.5. Refer to the Control
Source parameter description (P.000) in chapter 4 for more information on selecting
a drive control source.

3.4

The Display

The display portion of the keypad/display is a four-character, seven-segment LED.
At drive power-up, SELF is displayed as the drive performs power-up diagnostics.
During drive operation, the display indicates parameter numbers, parameter values,
fault or alarm codes, and the drive output values. Figures 3.2 and 3.3 show sample
displays.

3.4.1 Display Range

Normally, a minus (–) sign is used as one of the four characters in the display to
indicate a negative value. If a value (including the minus sign) exceeds four
characters, the display will drop the minus sign and display four digits. In this case,
the SPEED LED will flash to indicate that the displayed value is a negative number.
Refer to the examples in table 3.1.

A decimal point to the right of the last digit in the display indicates there is further
resolution (examples A and E) unless decimal point already appears as part of the
number displayed (example G). In either case, the system uses the full resolution of
the number for drive control, not the displayed value.

Display shows
menu selections:

P.---
H.--- (if P.048 = U-H)
U.--- (if P.048 = UEC)
r.--- (if optional RMI
board is installed)

or
Err (Error Log)

PROGRAM LED is on

ENTER

STOP

RESET

START

RUN

JOG

AUTO

MAN

Forward
Reverse

PROGRAM

SPEED
VOLTS
AMPS
Hz
Kw
TORQUE
Password

RUNNING
REMOTE
JOG
AUTO
FORWARD
REVERSE
PROGRAM