2-30

GV3000/SE 230 VAC Drive, Software Reference Version 6.04

Step 8.7 Self-tuning is now completed. If a zero is displayed, the self-tuning

procedure was completed successfully. Go to step 10.

If SF is displayed, the procedure was not successfully completed. Go to
step 9 to view parameter U.009 for a specific fault code.

When self-tuning is complete, the motor will
ramp to a stop.

The following parameters will be updated
based on the self-tuning results:

U.001 - Encoder PPR (if U.001

SE)

U.006 - Magnetizing Current

U.008 - Torque Self-Tune Enable (reset
to OFF)

U.009 - Torque Self-Tune Result

AUTO

MAN

Forward
Reverse

PROGRAM

RUN
JOG

STOP

RESET

START

ENTER

SPEED
VOLTS
AMPS
Hz
Kw
TORQUE
Password

RUNNING
REMOTE
JOG
AUTO
FORWARD
REVERSE
PROGRAM

Step 9. Check Self-Tuning Results

The results of the self-tuning procedure is displayed in U.009. This step describes
how to view the results if SF is displayed after the test is started.

Step 9.1 Press the PROGRAM key until the PROGRAM LED turns on to enter

program mode.

The display returns to the Vector (U)
parameters.

AUTO

MAN

Forward
Reverse

PROGRAM

RUN
JOG

STOP

RESET

START

ENTER

SPEED
VOLTS
AMPS
Hz
Kw
TORQUE
Password

RUNNING
REMOTE
JOG
AUTO
FORWARD
REVERSE
PROGRAM

Step 9.2 Press the ENTER key to access the Vector parameters.

The display shows U.008, the last parameter
accessed.

AUTO

MAN

Forward
Reverse

PROGRAM

RUN
JOG

STOP

RESET

START

ENTER

SPEED
VOLTS
AMPS
Hz
Kw
TORQUE
Password

RUNNING
REMOTE
JOG
AUTO
FORWARD
REVERSE
PROGRAM

Advertising