Detailed Drive Operation Chapter 1

Parameter 234 [Encdr 0/1 Error] indicates the status of the encoder when there is
an error.

The encoder blocks generate position feedback, seen in parameter 230 [Encdr0
Position] or parameter 240 [Encdr1 Position]. Encoder position is in quadrature
counts (the drive counts 4x the encoder PPR per motor revolution).

The encoder blocks generate speed feedback, seen in parameter 231 [Encdr0 Spd
Fdbk] and parameter 241 [Encdr1 Spd Fdbk].

Linear Feedback Devices

A Linear Feedback device requires a Multi-Device Interface (MDI) feedback
option card. Refer to the

PowerFlex 700S AC Drive Phase II Control Frames 1…6

Installation Instructions, publication

20D-IN024

, for information on supported

linear feedback devices.

Note

: the linear feedback devices can be used only for position feedback, and are

not used for motor speed feedback.

The position feedback (displayed in parameter 252 [FB Opt1 Posit]) counts at a
rate which depends on the linear feedback sensor used. Parameter 253 [FB Opt1
Spd Fdbk] contains the speed feedback from the linear feedback device.

231

230

241

240

233

232

242

234

Encoder 0

Processing

Encoder 1

Processing

Encdr 0/1 Error

To Feedback
Selection

To Feedback
Selection

Encoder0 PPR

Encoder1 PPR

Encdr 0/1 Cnfig

Encdr0 Position

Encdr0 Spd Fdbk

Encdr1 Position

Encdr1 Spd Fdbk