Position Reference Scaling

Position reference can be entered in user units by using the EGR scaling.
Parameters 745 [PositRef EGR Mul] and 746 [PositRef EGR Div] are used to
scale the position reference.

Example:

To use degrees of motor revolution for the positioning units, scale as follows:

With a 1024 encoder on the motor, this translates to 4096 counts per
revolution quadrature position counts.

This scaling translates the position reference of 0…360 degrees to 0…4096
position counts. This will allow you to enter degrees of motor rotation for
the position reference.

Position Offset

Offsets can be added to the position reference. Offset are used to make a
correction move to synchronize the follower to the master position.

There are two offsets, parameters 753 [Posit Offset 1] and 754 [Posit Offset 2].
The offset speed must be entered in parameter 755 [Posit Offset Spd] - if this is
left at zero the move will not occur. The position offset must be entered in counts

Parameter 745 [PositRef EGR Mul]

= 4096

Parameter 746 [PositRef EGR Div]

= 360

Gear Rat

[ N ]
[ D ]

745

746

PositRef EGR Mul

PositRef EGR Div

744

PositRef EGR Out

Geared Position
Reference

Selected Position

Reference

Deriv

Δ

+

Rate Lim

753

754

755

LPass

Filter

756

Posit Offset 1

Added to Position
Reference After EGR

Posit Offset 2

Posit Offset Spd

Position Control

(X Offset Pol)

Position Control

(X Offset Ref)

Deriv

Δ

740

04

740

05

741

05

Position Status
(XOffRRef Act)

X Offst SpdFilt

Advertising