Rockwell Automation 20D PowerFlex 700S AC Drives with Phase II Control Reference Manual User Manual

Page 137

Advertising
background image

Rockwell Automation Publication PFLEX-RM003E-EN-E - January 2011

137

Detailed Drive Operation Chapter 1

The following are the possible resolver settings:

Parameter 272 [Reslvr0 SpdRatio] specifies the speed ratio for the resolver option
card at port 0. The speed ratio comes from the following formula:

Speed ratio = electrical rev.s / mechanical rev.s = pole count / 2

Parameter 273 [Reslvr0 Carrier] specifies the resolver carrier frequency for the
resolver option card at port 0.

Parameter 274 [Reslvr0 In Volts] specifies the resolver input voltage for the
resolver option card at port 0.

Parameter 275 [Rslvr0 XfrmRatio] specifies the resolver transformation ratio for
the resolver option card at port 0.

Parameter 276 [Reslvr0 CableBal] specifies the resolver cable balance for the
resolver option card at port 0.

Parameter 269 [Resolver0 Status] indicates status of the resolver option card port
0. The bits are defined as follows:

• Bit 0 “-Cable Tune” indicates a cable tune is in progress.
• Bit 1 “-Tune Result” indicates the tuning parameter type. When set, it

indicates the tuning is using the parameter database. When cleared, it
indicates the tuning is using derived data.

• Bit 2 “-Mtr Turning” indicates that the motor is turning.
• Bit 3 “-Cable Comp”

Par 277
[Reslvr0 Type Sel]

Par 272
[Reslvr0 SpdRatio]

Par 273
[Reslvr0 Carrier]

Par 274
[Reslvr0 In Volts]

Par 275
[Reslvr0 XfrmRatio] Description

0 - Disabled

1

0

0

0.0

No resolver configured

1 -T2014/2087x1

1

2381

26

0.4538

Tamagawa, TS-2014N181E32, TS-
2087N1E9, TS-2087N11E9

2 -T2014/2087x2

2

2381

26

0.4538

Tamagawa, TS-2014N182E32, TS-
2087N2E9, TS-2087N12E9

3 -T2014/2087x5

5

2381

26

0.4538

Tamagawa, TS-2014N185E32, TS-
2087N5E9

4 - MPL 460v

1

4000

8

0.25

AB Motor with integrated Resolver

5 - Reserved

1

9300

22

0.5

Not supported

6 - Siemens 1FT6

1

4000

5

0.5

Siemens, 1FT6 series Motors with
integrated Resolver

7 - PrkrHn ZX600

1

7000

4.25

0.4706

Parker Hannifin, ZX600 series Motor with
integrated Resolver

8 - Reserved

1

2500

12

0.5

Not Supported for Speed Regulation

9 - 1326Ax 460v

1

4000

8

0.25

AB Motor with integrated Resolver

10 - Reserved

1

9000

15.5

0.5013

Not Supported for Speed Regulation

11 - Reserved

1

2500

7

1.7

Not Supported for Speed Regulation

12 - Reserved

1

9300

22

0.5

Not Supported for Speed Regulation

13 - Reserved

1

2000

6.36

0.5

Not Supported for Speed Regulation

14 - AmciR11XC107

1

2381

26

0.4538

Advanced Micro Controls, R11X-C107

15 - PowerTec R1

Not Used

16 - PowerTec R1

Not Used

Advertising