Detailed Drive Operation Chapter 1

The inertia compensation outputs the calculated torque to the parameter 59
[Inertia Trq Add]. [Inertia Trq Add] is summed with the output of the friction
compensation block and the torque generated by the speed reference loop. That
summed torque enters the torque selection block (refer to

Torque Reference on

page 193

for more information).

Parameter 55 [Speed Comp] contains the rate of acceleration or deceleration
calculated in the inertia compensation block. This parameter is used in following
applications. Link parameter 23 [Speed Trim 3] to [Speed Comp] and set
parameter 24 [SpdTrim 3 Scale] to 0.002 to reduce position error in following
applications.

Input Devices

Contactors

Refer to

Motor Start and Stop Precautions on page 74

Circuit Breakers/Fuses

See the

PowerFlex 700S AC Drives, Phase II Control Technical Data, publication

20D-TD002

, for Watts Loss data and curves.

Filters EMC

Refer to

CE Conformity on page 28

Input Modes

Refer to

Start and Stop Modes on page 176

.

Input Power Conditioning

Refer to the

Wiring and Grounding Guidelines for Pulse Width Modulated

(PWM) AC Drives Installation Instructions, publication

DRIVES-IN001

, for

detailed information.

56

9

57

58

43

Inertia Comp

Δ

n

Δ

t

Inertia SpeedRef

InertiaAccelGain

InertiaDecelGain

Total Inertia

Logic Command

(Inertia Comp)

59

Link

S Curve Spd Ref

Inertia Torq Add

to Torque

Control [4B1]

60

DeltaSpeedScale

151

10

55

Speed Comp