Rockwell Automation Publication PFLEX-RM003E-EN-E - January 2011

Chapter 1 Detailed Drive Operation

Parameter 253 [FB Opt1 Spd Fdbk] contains the speed feedback from the linear
sensor when the MDI option card is installed.

Parameter 249 [Fdbk Option ID] displays information about the feedback
option installed in feedback option card port 0. Options:

• Bits 15…11 contain the module ID number.
• Bits 10…6 contain the version number.
• Bits 5…3 contain the revision number high.
• Bits 2…0 contain the revision number low.

Hexadecimal 1000 indicates a resolver, hexadecimal 2000 indicates an old high-
resolution board, and hexadecimal 2040 indicates a new high-resolution board.

Stegmann Hi-Resolution Encoder Feedback Option

The position feedback (seen in parameter 250 [FB Opt0 Posit]) from a Stegmann
Hi-Resolution encoder counts at a rate of 1,048,576 counts per motor revolution.

Parameter 251 [FB Opt0 Spd Fdbk] contains the speed feedback from the
Stegmann Hi-Resolution encoder when connected at port 0.

Parameter 259 [Stegmann0 Cnfg] is used to configure the Stegmann Hi-
Resolution encoder.

• Bit 5 “Direction” determines the counting direction. If set to “0”, the

direction is forward or up. If set to “1”, the direction is reverse or down.

251

250

249

Feedback

Option Card 0

Processing

259

268

272

273

274

275

276

260

269

Stegmann0 Status

To Feedback
Selection

Resolver0 Status

263

264

Heidenhain0 Stat

Reslvr0 SpdRatio

Reslvr0 Carrier

Reslvr0 In Volts

Rslvr0 XfrmRatio

Reslvr0 CableBal

Stegmann0 Cnfg

Resolver0 Confg

Fdbk Option ID

Heidenhain0 Cnfg

FB Opt0 Spd Fdbk

FB Opt0 Posit

N N NNN

N N NNN

N NNN

N NNN

Module ID No. Version No.

Revision No. High Revision No. Low

Advertising