Detailed Drive Operation Chapter 1

Virtual Encoder Output to the Heidenhain Option Card

With firmware version 4.001 you can program the Heidenhain feedback option
for a scalable virtual encoder output. The virtual encoder output can be taken
from the speed reference section or linked to other feedback parameters and be
scaled to the desired EPR. The following parameters provide this functionality.

• Bit 7 “VM Direction” of parameter 263 [Heidenhain0 Cnfg]
• Bits 0 “VM Enc Out” and 1 “Emul Enc Out” of parameter 264

[Heidenhain0 Stat]

• Bit 6 “VrtlMasterEn” of parameter 266 [Heidn Encdr Type]
• Parameter 267 [Heidn Encdr PPR] with a minimum value of “1”.
• Bit 7 “EGR Enable” of parameter 1000 [UserFunct Enable]
• Parameter 1160 [VirtEncPositFast]
• Parameter 1161 [EGR Config]
• Parameter 1162 [EGR Mul]
• Parameter 1163 [EGR Div]
• Parameter 1164 [EGR Pos Input] (only linkable to Pars 250 [FB Opt0

Posit], 762 [Position Fdbk], and 1160 [VirtEncPositFast])

• Parameter 1165 [EGR Pos Output]
• Parameter 1166 [EGR Pos Preset]

VrtlMaster Encoder

Heidenhain0 Cnfg

(VM Direction)

1

266

06

Heidn Encdr Type

(VrtlMasterEn)

0

1162

1163

EGR Mul

EGR Div

1164

1155

1156

265

VrtlMaster PPR

Heidn Mkr Offset

Heidn VM Pos Ref

Heidenhain

Encoder

EGR Pos Output

EGR Pos Input

EGR

[ N ]
[ D ]

317

Update Time

Delay

Heidenhain Option Card

(C0E)

(C0F)

263

07

317

+

-

SL System Time

(at Position data update)

61

62

63

Virtual Encoder

Virt Encdr Posit (Task 2)

Virt Encdr Dlyed (Task 2)

Delay

One

Scan

1165

43

Ramped Spd Ref

Virt Encoder EPR

1160

VirtEncdrPositFast (Task 1)

Deriv

Δ

2

1

Accum

Σ

0

3

1161

01 00

0

1166

EGR Config

EGR Pos Preset

Output Selection

(C07)

(C0D)

(C09.bit22)

(C09.bit23)

(at beginning of VScan)