Syntax, Parameters – Dell PowerVault MD3420 User Manual

Page 216

Advertising
background image

The testID parameter takes the following options, which you can use to verify that a RAID controller
module is functioning correctly:

• 1 — Reads the test
• 2 — Performs a data loop-back test
• 3 — Writes the test

The diagnostic tests consist of loop-back tests in which data is written to physical disks and read from the
physical disks.

Syntax

diagnose raidControllerModule [(0 | 1)]

loopbackPhysicalDiskChannel=(allchannels | (1 | 2))

testID=(1 | 2 | 3)

[patternFile=”filename”]

Parameters

Parameter

Description

raidControllerModule

RAID controller module on which to run the
diagnostic tests. Valid RAID controller module
identifier values are 0 and 1. The identifier value is
0 for the RAID controller module on the top and 1
for the RAID controller module on the bottom
when viewed from the rear of the enclosure. You
must put brackets ([ ]) around the RAID controller
module identifier. If you do not specify a RAID
controller module, the storage management
software returns a syntax error.

loopbackPhysicalDiskChannel

Physical disk channel on which to run the
diagnostic tests. You can choose to run the
diagnostics on all channels or select a specific
channel on which to run diagnostics. Valid physical
disk channel values are 1 or 2.

NOTE: When you run a data loopback test,
you can optionally specify a file that contains
a data pattern. If you do not specify a file, the
firmware provides a default pattern.

testID

Identifier for the diagnostic test to run. The
identifier and corresponding tests are:

• 1 — Reads the test
• 2 — Write test
• 3 — Data loop-back test