Stop Configuration Database Diagnostic

Description

This command stops the diagnostic test to validate the configuration database in the RAID controller
module firmware that was started by the start storageArray configDbDiagnostic command.

Syntax

Stop storageArray configDbDiagnostic

Parameters

None.

NOTE: The RAID controller module firmware returns a confirmation that the diagnostic test was
cancelled. In addition, the database configuration diagnostic test can be started through the storage
management software GUI but cannot be stopped through the storage management software GUI.
If you want to stop a running diagnostic test, you must use the stop storageArray
configDbDiagnostic command.

Stop Consistency Group Snapshot Rollback

Description

This command stops a rollback operation to the member base virtual disks in a snapshot consistency
group that was initiated by the start rollback cgSnap command.

NOTE: Canceling a consistency group snapshot rollback operation leaves the base virtual disk in an
indeterminate state with potentially invalid or inconsistent data. The related consistency group
snapshot virtual disk becomes disabled and unusable.

Syntax

stop cgSnapImage["consistencyGroupName"]| rollback

[memberVirtualDiskSet ["memberVirtualDiskName1 ... memberVirtualDiskNamen"]]

Parameters

Parameter

Description

consistencyGroupName

The name of the consistency group for which you
want to stop a rollback operation. Enclose the
name of the consistency group in double
quotation marks (" ") inside square brackets ([ ]).
When the memberVirtualDiskSet parameter is
not used, the rollback process applies to all
member virtual disks of the consistency group.

memberVirtualDiskSet

The name of one or more member base virtual
disks in a consistency group that you want to stop