Recover sas port miswire – Dell PowerVault MD3420 User Manual

Page 233

Advertising
background image

Parameter

Description

NOTE: CopyPriority defines the amount of
system resources used to copy the data
between the source and target virtual disks of
a virtual disk copy pair. If you select the
highest priority level, the virtual disk copy uses
the most system resources to perform virtual
disk copy, which decreases performance for
host data transfers.

targetReadOnlyEnabled

Specifies whether the target virtual disk is write
enabled or read only. To be able to write to the
target virtual disk, set this parameter to FALSE. To
prevent writing to the target virtual disk, set this
parameter to TRUE.

copyType

Creates a virtual disk copy with or a snapshot
which enables you to continue to write to the
source virtual disk while creating the virtual disk
copy. To reinitiate a virtual disk copy with a
snapshot, set this parameter to online. To
reinitiate a virtual disk copy without a snapshot, set
this parameter to offline.

Recover SAS Port MisWire

Description

This command tells a RAID controller module that corrective action has been taken to recover from a
miswire condition. The RAID controller module can then re-enable any SAS ports that were disabled
because a miswire was detected. Run this command after you have corrected any SAS miswire
conditions.
SAS Miswire conditions can be one of these:

• Invalid SAS topologies
• RAID Controller Module host port to expansion enclosure connection
• Initiator to physical disk topology connection
• EMM miswire

Syntax

recover sasPort miswire

Parameters

None

Notes

When a miswire condition is detected the RAID controller module firmware reports the following:

233

Advertising