Show Storage Array Power Information

Description

This command returns information about the amount of power consumed by the entire storage array and
each enclosure in the storage array.

Syntax

show storageArray powerInfo

Parameters

None

Notes

This command returns power consumption information similar to this example.

total power drawn: 310 watts

number of enclosures: 1

enclosure power input details:

enclosure id power supply serial number input power

0 0 160 watts

0 1 150 watts

Show Storage Array Unconfigured iSCSI Initiators

Description

This command returns a list of initiators that have been detected by the storage array but are not yet
configured into the storage array topology.

Syntax

show storageArray unconfiguredIscsiInitiators

Parameters

None.

Show Storage Array Unreadable Sectors

Description

This command returns a table of the addresses of all of the sectors in the storage array that cannot be
read. The table is organized with column headings for the following information:

• Virtual disk user label
• Logical unit number (LUN)