Save physical disk log, Save raid controller module nvsram – Dell PowerVault MD3420 User Manual

Page 263

Advertising
background image

Parameter

Description

Valid values for the identifier number are 1 or 2.
Enclose the identifier number in square brackets
([ ]).

file

The name of the file in which you are storing the
results of the fault isolation diagnostics test on the
drive channel. Enclose the name in double
quotation marks (" ").

NOTE: A file extension is not automatically appended to the saved file. You must specify the
applicable format suffix for the file. If you specify a file extension of .txt, then the output is in a text
file format. If you specify a file extension of .xml, then the output is in an XML file format.

Save Physical Disk Log

Description

This command saves the log sense data to a file. Log sense data is maintained by the storage array for
each physical disk.

Syntax

save allPhysicalDisks logFile="filename"

Parameter

Parameter

Description

logFile

Name of the file to which to write the log sense

data. You must put quotation marks (" ") around the

file name.

Save RAID Controller Module NVSRAM

Description

This command saves a copy of the RAID controller module NVSRAM values to a file. This command saves
all regions.

Syntax

save raidControllerModule [(0 | 1)] NVSRAM file="filename"

Parameters

Parameter

Description

raidControllerModule

RAID controller module with the NVSRAM values to
save. Valid RAID controller module identifier values
are 0 and 1. The identifier value is 0 for the RAID

263