Stop Storage Array Blink

Description

This command turns off the indicator lights on the storage array that were turned on by the start
storageArray blink command.

Syntax

stop storageArray blink

Parameters

None.

Stop Storage Array Configuration Database Diagnostic

Description

This command stops the diagnostic test to validate the configuration database in the RAID controller
module firmware that was started by the start storageArray configDbDiagnostic command.

Syntax

stop storageArray configDbDiagnostic

Parameters

None.

Notes

The RAID controller module firmware returns a confirmation that the diagnostic test was cancelled.
In addition, you can start the database configuration diagnostic test through the storage management
software GUI; however, you cannot stop the database configuration diagnostic test through the storage
management software GUI. If you want to stop a running diagnostic test, you must use the stop
storageArray configDbDiagnostic command.