KEYENCE IG Series User Manual
Page 100

4-2 Basic Settings and Advanced Settings
4-42
4
Setting V
a
ri
o
us
F
u
nct
ion
s
IG-E
z
Display example of the normal setting
The range with the green LED ON is the measured target and the internal measurement
value (R.V.) is determined. If the green LED all lights off, the internal measurement value
(R.V.) is determined as [
].
CCD judges that the light enters only the range with the red LED ON (exceeding the
binarization level).
Display pattern 1
1. Measurement mode
: Edge control/Positioning [
C.GFI], Glass edge [F.INU]
2. Measurement direction : Top [
VQR]
Display pattern 2
1. Measurement mode
: Edge control/Positioning [
C.GFI], Glass edge [F.INU]
2. Measurement Direction : Bottom [DVO]
Display pattern 3
1. Measurement mode : Outer diameter/Width measurement [
D.FKC],
Pin interval judgment [
H.RKR], Pin diameter judgment [I.RKF]
Specified edge interval measurement [
J.WUT]
*1 When "Pin interval judgment mode" or "Pin diameter judgment mode" is set, this range
is not the internal measurement value (R.V.).
R.V.
R.V.
Transmitter
Receiver
Top
Bottom
Top
Bottom
Lights in red :
Lights in green :
Off :
R.V.
R.V.
Transmitter
Receiver
Top
Bottom
Top
Bottom
Lights in red :
Lights in green :
Off :
R.V.*
1
R.V.*
1
Transmitter
Receiver
Top
Bottom
Top
Bottom
Lights in red :
Lights in green :
Off :