4-2 Basic Settings and Advanced Settings

4-38

4

Setting V

a

ri

o

us
F

u

nct
ion
s

IG-E

Laser emission stop input

The laser emission continues to stop while the laser emission stop input is ON. The laser
emission indicator on the sensor amplifier lights off while the laser emission is stopped.

"Amplifier control unit" (page 1-10)

„ Timing chart

*1 After 2.5 ms (max.), the internal measurement value (R.V.) becomes [

].

„ Minimum Input Time

ON time: 2 ms
OFF time: 2 ms

Gain input

When the Gain input is set to ON, the standard waveform is registered (Gain adjustment).

"3-4 Registering the Standard Waveform (Gain adjustment)" (page 3-9)

„ Timing chart

*1 1.5 sec. is taken when "Nonvolatile memory (EEPROM) storage function" is set for

"12. Saving the standard waveform function".

„ Minimum Input Time

ON time: 20 ms
OFF time: 100 ms

*1

*1 1.5 sec. is taken when "Nonvolatile memory (EEPROM) storage function" is set for

"12. Saving the standard waveform function".

Reference

While the laser emission is stopped, the internal measurement value (R.V.)
shows [

].

"2 Display Screen and Output" (page A-9)

Max. 2 ms*

1

Max. 2 ms

Min. 2 ms

ON

OFF

Laser emission

stop input

Laser being transmitted

Laser being transmitted

Laser emission being stopped

Max. 120 ms*

1

Min. 20 ms

Before registering the standard waveform

Registering

The standard waveform registration complete

ON

OFF

Gain input