4-2 Basic Settings and Advanced Settings

4-9

IG-E

4

Setting V

a

ri

o

us
F

u

nct
ion
s

Edge control/Positioning mode

With this mode, the internal measurement value (R.V.) is
determined by measuring the distance from the edge of
the measurement range to the edge of the target. (light-
shielding object).
Use this mode for the edge control or positioning.

„ Details

z "2. Measurement direction" (page 4-17) When "Top" is selected

The distance from the top edge of the measuring range to the bottom most light to dark
transition as seen by the receiver is determined as an internal measurement value (R.V.).

z "2. Measurement direction" (page 4-17) When "Bottom" is selected

The distance from the top most light to dark transition as seen by the receiver to the bottom
of the measuring range is determined as an internal measurement value (R.V.).

Light-shielding
target

Measurement
range

R.V.

Top

Bottom

Measurement
range

R.V.

Top

Bottom

Reference

• If there is no object present , the internal measurement value (R.V.) becomes

[

].

"2 Display Screen and Output" (page A-9)

• If the target shields light of the entire measurement range, the entire

measurement range becomes the internal measurement value (R.V.).

R.V.

Top

Bottom

R.V.

Top

Bottom