4-4 Calculation Function

4-51

IG-E

4

Setting V

a

ri

o

us
F

u

nct
ion
s

When the calculation function is used, the calculation process is added. Therefore, the
response time is delayed.
According to the number of additionally installed expansion units, add the following time to
the average number of times (response time) set on the main unit.

"3. Average number of times (Response time)" (page 4-17)

*1

"14. Interference prevention function (only for IG-1000/1500)" (page 4-40)

Setting Method (Only Main Unit)

Main screen

1

Press [MODE] button and

W button for approx. 2

seconds on the main screen at the same time.

[

.ECN] is displayed on the main display (upper level).

[MODE] +

W button

2 seconds or more
at the same time

2

Press

S / T button to set the mode and press [MODE]

or

X button.

If there is no expansion unit additionally installed, the setting
cannot be changed from [

QHH].

[MODE] or
X button

Main screen

3

When settings other than "The calculation function is

not used" are set on the main screen, the calculation

indicator "CALC" lights up.



LASER

BANK

0

1

2

3

HI

GO

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT



HOLD

CALC

CHECK

Q((

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

%#.

GO

HOLD

CALC

CHECK

Mode

Setting

value

Description

Default

value

QHH

The calculation function is not used.

c

RNWU

Addition Mode

OKPWU

Subtraction Mode

JGCF

2 Heads Mode



LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT



HOLD

CALC

CHECK

GO

[CALC] ON

Response Time When the Calculation Function is Used

Number of installed units

(including the main unit)

Interference prevention

function

*1

OFF

Interference prevention

function ON

2

5 ms

7 ms

3

7 ms

7 ms

4

10 ms

14 ms

Reference

• When the calculation function is used, the setting of the average number of times

(Response time) for the expansion unit is the same as the one for the main unit.

• If connecting RS-232C Communication Unit DL-RS1A or the BCD Output Unit

DL-RB1A, add "7 ms" to the value in the table above.