KEYENCE IG Series User Manual
Page 140
6-4 Configuration Tab
6-18
6
IG Config
u
ra
tion Softw
a
re (
IG-
H1)
IG-E
Item
Description
Analog output
Scaling
Default value: Default
Upper limit
When the free range is set, the upper limit and lower limit can be
set.
Setting range : -99.999 to 99.999
Default value : 10.000
Lower limit
Setting range : -99.999 to 99.999
Default value : 0
External Input:
Function selection
Default value: Default
Input1(Pink)
When the User is set, each function of the external input 1 to 4 can be
set.
Setting range :
Zero
shift input/Bank A input/Bank B input/
Laser emission stop input/Not use
Default value :
Zero
shift input
Input 2 (Yellow)
Setting range : Reset input/Bank A input/Bank B input/
Laser emission stop input/Not use
Default value : Reset input
Input 3 (Pink/
Violet)
Setting range : Timing input/Bank A input/Bank B input/
Laser emission stop input/Not use
Default value : Timing input
Input 4 (Violet)
Setting range : Not use/Bank A input/Bank B input/
Laser emission stop input/Gain input
Default value : Not use
Saving the standard
waveform function
Default value: OFF (Do not save)
Saving zero shift value
function
Default value: OFF (Do not save)
Display Digit
Setting range : 0.001 / 0.01 / 0.1 / 1
Default value : 0.01
Power save function
Default value: OFF (Normally ON)
Position monitor
Setting range : Default (initial state)/ OK/NG display/Red : Off /
OFF
Default value : Default
Display color
Setting range
:
GO Green/ GO Red/ Normally Red
Default value : GO Green
Interference
prevention function
Default value : OFF