Waveform display, Monitor tool bar, Waveform display -21 monitor tool bar -21 – KEYENCE IG Series User Manual

Page 143

Advertising
background image

6-5 Monitor tab

6-21

IG-E

6

IG Config

u

ra

tion Softw

a

re (

IG-
H1)

This displays the receiving status of the light-receiving element (CCD) as a waveform.

These are buttons to operate the waveform display.

Waveform Display

Item

Description

Horizontal
axis

Shows the measurement range of the sensor head. Top side: 0 mm

"Sensor Head Unit" (page 1-12)

Vertical axis

Shows the light-receiving amount of each pixel of CCD. Display range: 0 to 255

Light-receiving
waveform

Displays the waveform with the red wire which presents the light-receiving
amount of each pixel of CCD

Binarization
Level

Displays the waveform with the light-blue wire which presents the
binarization level of each pixel of CCD.
When the light-receiving waveform rises above the binarization level, it is
judged as received light. When the light-receiving waveform falls below the
binarization level, it is judged as light-blocked.

"4-3 Setting the Measurement Sensitivity" (page 4-44)

Edge used
for measure-
ment.

The edge is the meeting point of the light-receiving waveform and the binarization
waveform. The edge used for measurement is displayed with a green wire.
Positions and the number of edges change depending on the measurement
mode even if it is the same target.

"1. Measurement mode" (page 4-8)

Note

The waveform is displayed in the abbreviated form of the data processed inside the sensor.
Therefore, the display may not agree completely to the sensor measurement status.

Monitor Tool Bar

Item

Description

Display of
binarization level

Display/No display of the binarization level can be switched by clicking.

"4-3 Setting the Measurement Sensitivity" (page 4-44)

Horizontal axis :
Zoom in

Enlarges the horizontal axis of the waveform display. Cannot
enlarge when the button is grayed out.

Horizontal axis :
Zoom out

Reduces the horizontal axis of the waveform display. Cannot
reduce when the button is grayed out.

Vertical axis :
Zoom in

Enlarges the vertical axis of the waveform display. Cannot
enlarge when the button is grayed out.

Vertical axis :
Zoom out

Reduces the vertical axis of the waveform display. Cannot
reduce when the button is grayed out.

Start

Start updating the waveform display by clicking.

Pause

Stops updating the waveform display by clicking.

The setting of the sensor amplifier being monitored and the
measurement state are saved in a file.
The button operation is enabled only when updating the wave
display is stopped.

Advertising