4-2 Basic Settings and Advanced Settings

4-21

IG-E

4

Setting V

a

ri

o

us
F

u

nct
ion
s

Sample hold

When the timing input is turned ON, the judgment value (P.V.) is held.

„ When "Level" is set for "6. Timing input" (page 4-27)

The sampling period is from the falling edge of the timing input to the next rising edge. On
the rising edge, the judgment value (P.V.) is held.

*1 The main unit (IG-1000/IG-1500)displays the calculation value (CALC value) when the

calculation function is used.

"4-4 Calculation Function" (page 4-47)

„ When "Edge" is set for "6. Timing input" (page 4-27)

The sampling period is from the rising edge of the timing input to the next rising edge of the
timing input. On the rising edge, the judgment value (P.V.) is held.

*1

"11. External input" (page 4-33)

*2 The main unit (IG-1000/IG-1500)displays the calculation value (CALC value) when the

calculation function is used.

"4-4 Calculation Function" (page 4-47)

Display value

Time

Judgment value (P.V.)
Internal measurement value (R.V.)*

1

Timing Input ON

OFF

Display value

Time

Judgment value (P.V.)
Internal measurement value (R.V.)*

2

Timing Input ON

OFF

Power ON or
Reset input *

1

After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.