Operation When the Power is Turned on for the First Time

When the amplifier is turned on for the first time after the sensor head is connected, the
initial setting screen appears after a few seconds. Make the initial settings according to the
following procedure.
The initial setting is necessary for both the main unit and the expansion units when units
are added.

4

Perform "3-3 Optical Axis Alignment" (page 3-8) and "3-4 Registering the

Standard Waveform (Gain adjustment)" (page 3-9).

Make other settings as necessary.

Note

The initial setting screen appears only when the power is turned on for
the first time. It will not appear when the power is turned on again. To
change these settings, perform the initial reset.

"3-5 Initial Reset (Initialize)" (page 3-10)

1

Press

S / T button to select the polarity of judgment

output and edge check output, and then press [MODE]

button.

[MODE] button

2

Press

S / T button to select the type of analog output

and press [MODE] button.

"10. Analog output scaling" (page 4-32)

[MODE] button

3

After the setting is complete, [

GPF] blinks several

times on the sub display and the main screen

appears.

Power ON

PRP

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

QWV

GO

HOLD

CALC

CHECK

Output polarity

Setting value

Description

PRP

NPN output

RPR

PNP output

QHH

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

#P.)

GO

HOLD

CALC

CHECK

Analog output

Setting value

Description

QHH

Not output

W

Analog output after the judgment value (P.V.) is converted
to the range from 0 to 5 V.

W

Analog output after the judgment value (P.V.) is converted
to the range from -5 to 5 V.

W

Analog output after the judgment value (P.V.) is converted
to the range from 1 to 5 V.

CORT

Analog output after the judgment value (P.V.) is converted to
the range from 4 to 20 mA.