2-1 Mounting and Wiring the Sensor Amplifier

2-7

IG-E

2

In

s

ta

lla

tion

a

nd C

onnection

Power/Input-output cable

"Output Circuit Diagram" (page 5-4)

*1 IG-1050/IG-1550 (expansion units) do not have brown, blue or light blue wires.

Power is supplied to the expansion units through IG-1000/IG-1500 (main unit).

*2 The analog output can be set to either "When the power is turned on for the first time"

or "When performing the initial reset".
• Not used (OFF)
• 0 to 5 V
• -5 to 5 V
• 1 to 5 V
• 4 to 20 mA

"3-1 Operation When the Power is Turned on for the First Time" (page 3-2)
"3-5 Initial Reset (Initialize)" (page 3-10)

*3 The external input can be selected among the following in addition to the above.

• Bank A input
• Bank B input
• Laser emission stop input
• Not used (OFF)
Gain input can be selected only for the external input 4.

"11. External input" (page 4-33)

Brown

Blue

Black

White

Gray

Light blue

Orange

Shield

Pink

Yellow

Pink/Purple

Purple

Green

10 to 30 VDC

0 V

HIGH judgment output

LOW judgment output

GO judgment output

Analog output +

Analog output GND

External input 1 (Zero shift input)

External input 2 (Reset input)

External input 3 (Timing input)

External Input 4 (Gain input)

Edge check output

*1

*1

*1

*2

*2

*3

*3

*3

*3

Advertising