Setting method, Setting method -46, 75tp – KEYENCE IG Series User Manual

Page 104: 3 setting the measurement sensitivity, Reference, Setting v a ri o us f u nct ion s ig-e, Main screen, X button (when [ wut] is selected), X button, Mode] or x button

Advertising
background image

4-3 Setting the Measurement Sensitivity

4-46

4

Setting V

a

ri

o

us
F

u

nct
ion
s

IG-E

Setting Method

Main screen

1

Press

W button and X button for approx. 2 seconds on

the main screen at the same time.

W + X button
2 seconds or more
at the same time

2

Press

S / T button to set the sensitivity setting and

press

X button.

When selecting settings other than "User", the main screen is
restored.
When the "User" is selected, go to step 3.

When the glass edge mode is selected for the measurement
mode, the value in [ ] is determined.

"1. Measurement mode" (page 4-8)

X button
(When [

WUT] is

selected)

3

Press

S / T button to set the binarization level and

press

X button.

X button

4

Press

S / T button to set the filter value and press

[MODE] or

X button.

The main screen is restored.

[MODE] or
X button

Reference

• When the [MODE] button is pressed during setting, the main screen is

restored while the settings made so far remain effective.

• When

W button is pressed, the display returns to the previous screen.



LASER

BANK

0

1

2

3

HI

GO

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT



HOLD

CALC

CHECK

&'(.6

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

5'P

GO

HOLD

CALC

CHECK

Sensitivity mode

Setting

value

Description

Binarization

level

Filter value

Default

value

JK

High sensitivity mode
This mode is for
measuring glass, small
targets, thin film or
transparent target.

60%

4

FGHNV

Standard mode

25% [60%]

9[4]

c

NQ

Low sensitivity mode
This mode tends not to be
influenced by dirt stuck to
the transmitter/receiver.

15%

41

WUT

User

10% to 90%

Default value 25%

3 to 50

Default value 9

DKP

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

75T$

GO

HOLD

CALC

CHECK

Binarization level

(.6

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

75TP

GO

HOLD

CALC

CHECK

Noise filter value

Main screen

Advertising