2-2 Connecting and Mounting the Sensor Head

2-14

2

In

s

ta

lla

tion

a

nd C

onnection

IG-E

Attaching the sensor head cable connector (OP-84338)

Cut the sensor head connection cable to the required length and attach the new connector
to use the sensor. The attaching method is the same for both transmitter and receiver.

1

Cut the cable to the required length and strip approx. 15 mm of insulation

from the end of the cable.

2

Insert each cable to the end matching to the same color marks on the

connector.

The cables are inserted to the end and tentatively fixed.

3

Confirm that all cables are inserted to the specified position and crimp

them tight parallel using a plier or similar tool.

Note

Do not strip the core wire insulation.

Note

If the connector is changed, make sure to connect it to the
amplifier and confirm the normal operation.
If it does not operate normally, crimp the connector again with a
plier.
Once the connector is crimped, it cannot be reused.

Blue

White

Black

Brown

Insert further
than here.

Advertising