Sensor head connection, Sensor head connection -12 – KEYENCE IG Series User Manual

Page 34

Advertising
background image

2-2 Connecting and Mounting the Sensor Head

2-12

2

In

s

ta

lla

tion

a

nd C

onnection

IG-E

Connecting the sensor head and sensor amplifier

1

Connect the sensor head connection cable to the transmitter and receiver

cables respectively.

2

Connect the sensor head connection cable on the receiver side to the [R]

connector of amplifier.

Sensor Head Connection

Note

Tighten the connectors securely with hand. If loosely tightened,
the environment resistance IP67 cannot be guaranteed.

Remove the lock cover of the connector and
insert it to the connector (R) of amplifier until a
clicking sound can be heard.

DIN rail mount type
(IG-1000/IG-1050)

Panel mount type
(IG-1500/IG-1550)

(1) Align the arrow position of the connector to insert.
(2) Rotate the connector screw to tighten.

The red O-ring is attached to the transmission cable and
blue O-ring to the receiver cable. Connect the sensor head
connection cable with red O-ring to the transmitter and
connect the sensor head connection cable with blue O-ring
to the receiver.

Unlocked

Lock cover

Click

Down: R side

Blue O-ring

Right: R side

Advertising