4-2 Basic Settings and Advanced Settings

4-37

IG-E

4

Setting V

a

ri

o

us
F

u

nct
ion
s

Bank A input/Bank B input

By combining ON/OFF setting of bank A input and bank B input, you can switch the banks.

"3-8 Bank Function (Registering Multiple Tolerance Setting Values)" (page 3-18)

„ Timing chart

*1 When the bank is switched, the internal measurement value (R.V.) shows [

] until

the average number of times (response time) elapses.

"3. Average number of times (Response time)" (page 4-17)

„ Minimum Input Time

ON time: 20 ms
OFF time: 20 ms

Reference

When the judgment value (P.V.) is held using the hold function, the judgment
value (P.V.) remains held even if ON/OFF for bank A input or bank B input is
switched. However, the judgment output changes according to the setting value
set for the new bank.

"5. Hold function" (page 4-20)

Judgment value
(P.V.) judgment
output

Within the
response time

[

]*

1

Within the
response time

Within the
response time

Max. 8 ms

Max. 20 ms

Max. 20 ms

Min. 20 ms

ON

OFF

Bank A input

ON

OFF

Bank B input

Max. 20 ms

Bank 1

Bank 2

Bank 3

Bank 0

[

]*

1

[

]*

1

In this example, after 8 ms have passed, Bank A
and Bank B are judged as OFF and operation at
Bank 0 may be performed during a certain period.