2-2 Connecting and Mounting the Sensor Head

2-11

IG-E

2

In

s

ta

lla

tion

a

nd C

onnection

Mounting from the bottom

Fix using the commercially available screws.

IG-010: M3, board thickness +4 mm or less
IG-028: M3, board thickness +5 mm or less

Tightening torque: 1.6 N·m or less

When the mounting bracket (IG-TB01/IG-TB02) is used

1

Attach the mounting bracket to the sensor head.

Press the sensor head to the mounting bracket firmly and fix with the included
hexagon socket head bolt (M3, length: 5 mm).
Tightening torque: 1.6 N·m or less

2

Fix through the mounting holes from the upper part of the mounting bracket.

Use the commercially available hexagon socket head bolt (M4) to fix the mounting
bracket through its holes.

IG-010

IG-028

IG-010

IG-028

Note

Press the sensor head to the mounting
bracket firmly and fix.

IG-010

IG-028