6-4 Configuration Tab

6-16

6

IG Config

u

ra

tion Softw

a

re (

IG-
H1)

IG-E

Sensitivity tab

Reference

For details on each function, refer to the sections below.

"4-3 Setting the Measurement Sensitivity" (page 4-44)

"3-8 Bank Function (Registering Multiple Tolerance Setting Values)" (page 3-18)

Item

Description

Sensitivity setting

Measures the measurement sensitivity for each bank.
The same setting range and default value are set for each bank.

Setting range : High sensitivity/Default/Low sensitivity/User
Default value :

Default

Binarization Level

If the User is set, the binarization level and filter value can be set.

Setting range : 10 % to 90 %
Default value : 25 %

Filter Value

Setting range : 3 to 50
Default value : 9

Main panel switching tab