4 configuration tab, Measurement mode tab, Configuration tab -14 – KEYENCE IG Series User Manual
Page 136: Measurement mode tab -14, Configuration tab

6-14
IG-E
6
IG Config
u
ra
tion Softw
a
re (
IG-
H1)
6-4
Configuration Tab
When the configuration tab is selected, the sensor amplifier can be set. The following four
tabs can be selected on the main panel switching tab.
Measurement mode, Threshold/Target value for shift, Sensitivity, Advanced Settings(Pro)
*1 According to the measurement mode, the displayed content varies.
Edge control/Positioning mode, Glass edge mode, Pin position measurement mode
: Measurement Direction
Outer diameter/Width measurement mode, Inner diameter/Opening measurement mode : No display.
Pin interval judgment mode, Pin diameter judgment mode
: Number of the pins
Specified edges interval measurement mode
: Edge number 1, Edge number 2
Measurement mode tab
Reference
For details on each function, refer to the sections below.
"4-4 Calculation Function" (page 4-47)
"1. Measurement mode" (page 4-8)
"2. Measurement direction" (page 4-17)
"3. Average number of times (Response time)" (page 4-17)
Item
Description
Calculation
mode
This can be set when more than one expansion units are additionally installed to the amplifier.
Setting range
: OFF (not used)/addition mode/subtraction mode/2 heads mode
Default value : OFF
Measurement
mode
Sets the measurement mode. The descriptions for the selected measurement mode are displayed at right.
Default value : Edge control/Positioning mode
Measurement
direction
*1
Sets the measurement direction. The descriptions for the selected measurement direction are displayed at right.
Setting range : Top/Bottom
Default value : Top
Average
number of
times
Sets the average number of times.
Setting range
: High speed (
hsp) / 1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 /
512 / 1024 / 2048 / 4096
Default value : 16
Output mode
Sets the output mode.
Default value : N.O.
Main panel switching tab