Pin interval judgment mode, 2 basic settings and advanced settings, Details – KEYENCE IG Series User Manual

Page 72: Number of pins-specifying screen, Reference, Setting v a ri o us f u nct ion s ig-e, The hold function is fixed to the sample hold, The analog output is fixed to the lower limit, 6 setting the tolerance setting value" (page 3-11), Hold function" (page 4-20)

Advertising
background image

4-2 Basic Settings and Advanced Settings

4-14

4

Setting V

a

ri

o

us
F

u

nct
ion
s

IG-E

Pin interval judgment mode

The intervals (openings) of transmitted light as seen by
the receiver are measured and judged if they are all
within the acceptable range.

„ Details

The number of intervals is specified on the number of pins-specifying screen. If the all pin
intervals are within the acceptable range, GO judgment is output. If even only one interval
is out of the acceptable range, HIGH judgment is output.

"3-6 Setting the Tolerance Setting Value" (page 3-11)

When this mode is used, the judgment value (P.V.) and the internal measurement value
(R.V.) represent the measured pin intervals.
When

S or T button is pressed on the screen displaying the judgment value (P.V.) and the internal

measurement value (R.V.), the number of pin interval counting from the top is displayed can be changed.

(example) When the number of pins is set to 3

„ Number of pins-specifying screen

When the pin interval measurement mode is set, the display goes to the number of pins-
specifying screen.

Press

S / T button on the number of pins-specifying screen to specify the number of pins.

Note

• The hold function is fixed to the Sample hold.

"5. Hold function" (page 4-20)

• The analog output is fixed to the lower limit.

"10. Analog output scaling" (page 4-32)

• If the zero shift function is used, the

average value of intervals of all pins being
measured shifts to the shift target value.

"3-7 Zero Shift Function (Shifting the Internal
Measurement Value (R.V.))" (page 3-16)

Reference

If the number of pins existing within the measurement range differs from the
specified number and the top and bottom edges of CCD is light-blocked, the
internal measurement value (R.V.) becomes [

].

"2 Display Screen and Output" (page A-9)

Measurement
range

d1

d1 and d2 show pin intervals.

d2

Top

Bottom

Item

Setting range

Default value

Number of the pins

2 to 14

2

( 2KR

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

 (PE

GO

HOLD

CALC

CHECK



LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

 #W'

GO

HOLD

CALC

CHECK

LASER

BANK

0

1

2

3

HI

GO

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

HOLD

CALC

CHECK



2KP

1. Measurement mode

Number of pins-specifying screen

3. Average number of times

[MODE]
or

X

[MODE]
or

X

Advertising