6-4 Configuration Tab

6-17

IG-E

6

IG Config

u

ra

tion Softw

a

re (

IG-
H1)

Advanced settings tab (Pro)

Reference

For details on each function, refer to the sections below.

"4-2 Basic Settings and Advanced Settings" (page 4-4)

Item

Description

Hold Function

Setting range : Sample hold/Peak hold/Bottom hold/

Peak-to-peak hold/Auto peak hold/
Auto bottom hold

Default value : Sample hold

Trigger level

When the Auto peak hold or Auto bottom hold is set, the trigger level
can be set.

Setting range : -99.999 to 99.999
Default value : 0.100

Timing Input

When settings other than the Auto peak hold or Auto bottom hold
are set, the timing input can be set.
Default value : Level

Delay Timer

Setting range : OFF (not used)/ON-delay/OFF-delay/1-shot
Default value : OFF

Timer value

When values other than OFF are set, the delay time can be set.

Setting range : 1 to 9999
Default value : 60

Hysteresis

Setting range : 0.000 to 99.999
Default value : 0.020

Edge check function

Default value: OFF

Number of edges

When values other than OFF are set, the number of edges can be
set.

Setting range : 0 to 99
Default value

:

1

Main panel switching tab