Setting the Tolerance Setting Value

The tolerance setting value consists of the upper limit value (HIGH side setting value) and
the lower limit value (LOW side setting value). By setting these values, judgments are made
in three levels: when the judgment value (P.V.) goes beyond the upper limit (HIGH
judgment), when the judgment goes beyond the lower limit (LOW judgment) and when the
judgment is within the acceptable range (GO judgment). Then, the judgment indicator and
judgment output are turned ON/OFF.

*1 When the output mode of judgment output is Normal Open (default value) ON/OFF is

reversed for Normal Close.

"4. Output mode" (page 4-19)

*2 The judgment indicator ON/OFF condition can be changed.

"18. Display Color" (page 4-43)

*3

"Error displays and corrective actions" (page A-4)

The tolerance setting value can be set either manually or automatically.

judgment

judgment output

*1

judgment indicator

*2

HIGH

GO

LOW

HI

GO

LO

HIGH

ON

OFF

OFF

Lights in red

Off

Off

GO

OFF

ON

OFF

Off

Lights in green

Off

LOW

OFF

OFF

ON

Off

Off

Lights in red

Error

*3

ON

OFF

ON

Lights in red

Off

Lights in red

DIN rail mount type (IG-1000/IG-1050)

Panel mount type (IG-1500/IG-1550)

Item

Setting Method

Manual setting

Directly enter the tolerance setting value (HIGH side
setting value, LOW side setting value).

Automatic
setting

Tolerance tuning

Detect the master workpiece and set the tolerance.

Two-point tuning

Detect the good target and defective target and set the tolerance.

Note

When setting the tolerance setting value manually using the two-point
tuning, make sure to set "HIGH side setting value

! LOW side setting value".

Reference

When setting "HIGH side setting value

! LOW side setting value", the judgment

output is as follows.
• GO judgment output is not output regardless of the judgment value (P.V.).

(When setting HIGH side setting value = LOW side setting value = judgment value
(P.V.) and setting the hysteresis to 0.000, GO judgment output is turned on.)

• When the judgment value (P.V.) goes beyond the HIGH side setting value

and falls below the LOW side setting value, the HIGH judgment output and
LOW judgment output are output at the same time.