Hysteresis, Hysteresis -30 – KEYENCE IG Series User Manual

Page 88

Advertising
background image

4-2 Basic Settings and Advanced Settings

4-30

4

Setting V

a

ri

o

us
F

u

nct
ion
s

IG-E

The hysteresis for the tolerance setting value is set.
If the judgment value (P.V.) fluctuates due to the vibration of the object, etc. and the
judgment output repeats ON/OFF, increasing the hysteresis value stabilizes ON/OFF.

"3-6 Setting the Tolerance Setting Value" (page 3-11)

8. Hysteresis

Item

Setting range

Default value

Hysteresis

0.000 to 99.999

0.020

Reference

The above is the timing chart when the output mode of judgment output is
Normally Open (default value). ON/OFF is reversed for Normally Close.

"4. Output mode" (page 4-19)

Time

Hysteresis

Hysteresis

Judgment value (P.V.)

HIGH side setting value

LOW side setting value

ON

OFF

ON

OFF

ON

OFF

HIGH judgment output

GO judgment output

LOW judgment output

Advertising