Auto bottom hold, Wvqd, 2 basic settings and advanced settings – KEYENCE IG Series User Manual

Page 84: Trigger level setting screen, Reference, Setting v a ri o us f u nct ion s ig-e, 4 calculation function" (page 4-47), Mode] or x [mode] or x

Advertising
background image

4-2 Basic Settings and Advanced Settings

4-26

4

Setting V

a

ri

o

us
F

u

nct
ion
s

IG-E

Auto bottom hold

When the internal measurement value (R.V.) falls below the specified trigger level, the
sampling begins. When it goes beyond the trigger level, the sampling finishes. When the
sampling finishes, the internal measurement value (R.V.) minimized during the sampling
period is held as a judgment value (P.V.).
The external input is not required.

*1

"11. External input" (page 4-33)

*2 After the power is turned on or reset is input, the judgment value (P.V.) is [

] until

the judgment value (P.V.) is first held.

*3 While the timing input is ON, the sampling does not start. If the sampling is already in

process, it continues.

*4 The main unit (IG-1000/IG-1500) displays the calculation value (CALC value) when the

calculation function is used.

"4-4 Calculation Function" (page 4-47)

„ Trigger level setting screen

When the Auto bottom hold is set, the display goes to the trigger level setting screen.

Press

S / T button on the trigger level setting screen to specify the trigger level.

Reference

• The operation by the timing input is the same regardless of the "6. Timing

input" (page 4-27) setting.

• After the sampling starts, if the internal measurement value (R.V.) becomes

"

" before the sampling goes beyond the specified trigger level, the

sampling is automatically finished and the minimized value during the
sampling period is held as a judgment value (P.V.).

Display value

Time

Timing Input

Trigger level

Hysteresis

ON

OFF

Power ON or
Reset input *

1

*

3

*

2

Judgment value (P.V.)
Internal measurement value (R.V.)*

4

Item

Setting range

Default value

Trigger level

-99.999 to 99.999

0.100

Reference

The hysteresis presents the same value as the one set for "8. Hysteresis"
(page 4-30).



LASER

BANK

0

1

2

3

HI

GO

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

VT)

HOLD

CALC

CHECK

#WVQD

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

 *.&

GO

HOLD

CALC

CHECK

QHH

LASER

BANK

0

1

2

3

HI

LO

R.V.

ANALOG

HI

SHIFT

ZERO SHIFT

TIMING

LO

ALIGNMENT

 &.;

GO

HOLD

CALC

CHECK

5. Hold function

Trigger level setting screen

7. Delay timer

[MODE]
or

X

[MODE]
or

X

Advertising