Chapter 7 I/O Terminals

7

Timing Chart

This section provides information on the timing charts of BCD output in a variety of meas-
uring modes.

Normal, Auto Peak Hold, Auto Bottom Hold, and Auto Peak-to-peak
Hold

ON

OFF

TIMING input

ON

OFF

RESET/ZERO input

ON

OFF

P1 input to P4 input

ON

OFF

Comparator output

ON

OFF

WAITING output

ON

OFF

ON

OFF

STROBE output

BCD output

Refresh cycle

STROBE time

0

±

0.1ms

Min

Min2.1ms

Min2.1ms

Max2.5ms

RESET

time

Max2.5ms

Max2.5ms

2.1ms

Min

2.1ms

Min6.0ms

Max12.0ms

Min

6.0ms

RESET

time

• The refresh cycle and reset time vary with the setting of the averaging number.

Refer to Reset Time and Refresh Cycle on page 7-13 for detail.

• The strobe output time can be changed. If the time set exceeds the refresh cycle time,

the strobe output will be always ON.
Refer to Strobe Output Time on page 5-47 for detail.

Peak Hold, Bottom Hold, Peak-to-peak Hold, Average Hold, and
Sample Hold 1

ON

OFF

TIMING input

ON

OFF

RESET/ZERO input

ON

OFF

P1 input to P4 input

ON

OFF

Comparator output

ON

OFF

WAITING output

ON

OFF

ON

OFF

STROBE output

BCD output

STROBE time

0

±

0.1ms

Min2.1ms

Min

2.1ms

Min2.1ms

Min2.1ms

Max2.5ms RESET

time

RESET

time

Sampling

period

Sampling

period

Max2.5ms

Max2.5ms

Min6.0ms

Min

6.0ms

Max12.0ms

• The strobe output time can be changed.

Refer to Strobe Output Time on page 5-47 for detail.

• Reset time varies with the setting of the averaging number.

Refer to Reset Time and Refresh Cycle on page 7-13 for detail.

• When RESET input turns ON, the internal measured value will be determined with an

elapse of reset time.