KEYENCE LS-7600 User Manual

Page 42

Advertising
background image

3-2

3

Chapter 3 Easy Setting Guide

Measurement of Outer Diameter and Width (with Single Measuring Head)

In the following example, a single measuring head is used to measure the outer diameter
of an object in one direction. The result of measurement is displayed as OUT1.

D

Measures the outer diameter in one direction.

Set Values

Set item

Calibration

Tolerance setting

Area setting

Output

setting

AREA

Operation

Averaging

RUN mode

Offset

Set value

AREA 1

Head 1 DIA

Make settings if required.

A1: +1

A2: 0

Select the value according to the line speed.

Normal

No settings are required.

No settings are required.

No settings are required.

Set the upper and lower limit values.

AREA 2

OUT 1

OUT 2

Reference

Area Settings (Page 5-9)
Calibration Settings (Page 5-22)
Output Settings (Page 5-29)
Tolerance Settings (Page 5-49)