Measurement of movement and positioning – KEYENCE LS-7600 User Manual
Page 47
Advertising

3-7
3
Chapter 3 Easy Setting Guide
Measurement of Movement and Positioning
In the following example, the movement or position of the workpiece is measured. The
result of output is displayed as OUT1.
■
Set Values
Set item
Calibration
Tolerance setting
Area setting
Output
setting
AREA
Operation
Averaging
RUN mode
Offset
Set value
AREA 1
Head 1 SEG.
(0E, +2E)
Make settings if required.
A1: 1
A2: 0
Select the value according to the line speed.
Normal
No settings are required.
No settings are required.
No settings are required.
Set the upper and lower limit values.
AREA 2
OUT 1
OUT 2
■
Reference
Area Settings (Page 5-9)
Calibration Settings (Page 5-22)
Output Settings (Page 5-29)
Tolerance Settings (Page 5-49)
Advertising