Mode specifications, Run mode, Program mode – KEYENCE LS-7600 User Manual

Page 201: Others, Chapter 9 specifications

Advertising
background image

9-7

Chapter 9 Specifications

9

Mode Specifications

RUN Mode

Status

Measured value display

Output

RS-232C

Numeric display Comparator display 5-level discrimination WAITING STROBE Analog output BCD ALARM FUNCTION Reception Response

Measuring

Positive-
side range
over

+FFFFFFF

Reference value: HI
Threshold: HH

OFF

+All

digits: F

OFF

Value

Measured value Comparator output Comparator output

OFF

Value

OFF

Negative
side range
over

–FFFFFFF

Reference value: LO
Threshold: LL

OFF

–All

digits: F OFF

Reset processing

– – – – – – –

OFF

OFF

ON

OFF

Comparator waiting voltage All digits: B OFF

Error

Error-0

None

OFF

OFF

OFF

+

10.5

+All

digits: B

ON

OFF

Error
response

Comparator
waiting

– – – – – – –

OFF

OFF

ON

Depends
on
measuring
mode

+All

digits: B

OFF

Not
synchronized
with set
conditions

O

O

O

O

O

O

O

O

O

O

O

Voltage according to
the measured value.
+10.5 V on the
positive side and
–10.5 V on the
negative side if the
voltage range is not
within

±

10 V.

Reference value: HI
Threshold: HH

Reference value: LO
Threshold: LL

Comparator

waiting

voltage

PROGRAM Mode

Status

Measured value display

Output

RS-232C

Numeric display

Comparator display 5-level discrimination WAITING STROBE Analog output

BCD ALARM FUNCTION Reception Response

Tolerance

setting

Same as the condition in

RUN mode operation

None

None

None

None

None

Same as the condition in RUN mode operation

Error
response

O

OFF

ON

OFF

Comparator

waiting voltage

All

digits: B

OFF

OFF

Area setting

Other than
level setting

Same as the condition in RUN mode operation

Error
response

O

Level
setting

Environment setting

Other than
LED inspection

LED
inspection

Same as the condition in

RUN mode operation

Same as the condition in

RUN mode operation

Optical waveform

and threshold

Error
response

O

Output setting

Same as the condition in RUN mode operation

Same as the condition in RUN mode operation

Same as the condition in RUN mode operation

Error
response

O

Calibration

setting

Each area

value

OFF

ON

OFF

Optical

waveform

All

digits: B

OFF

OFF

None

Error
response

O

Expansion

setting

Error
response

O

Error
response

O

Error
response

O

Same as the condition in

RUN mode operation

None

None

None

None

None

None

None

Others

Status

Measured value display

Output

RS-232C

Numeric display

Comparator display 5-level discrimination WAITING STROBE Analog output

BCD

ALARM FUNCTION Reception Response

Power-ON reset
processing

- - - - - - -

None

OFF

OFF

OFF

0V

+All

digits: 0

ON

OFF

Error
response

O

• The LS-7600 Series will be reset if the LS-7600 Series is set to RUN mode from

PROGRAM mode.

• After a program number change is made, the LS-7600 Series will be reset on comple-

tion of auto zero processing.

• The LS-7600 Series will be reset if a set value change is made over RS-232C.
• If an ERROR-0 occurs during power-ON reset processing, the analog output will be

set to 0 V and all the digits of the BCD output will be added with 0.