Area calculation – KEYENCE LS-7600 User Manual

Page 92

Advertising
background image

5-30

Chapter 5 Function Settings

5

Making Output Settings for OUT1

(1) Press the [ENT] key.

Making Output Settings for OUT2

(1) Press the [Down] key to move the

cursor frame to OUT2.

(2) Press the [ENT] key.

OUT1

CALC

+1A1 +0A2

AVE

512

MEA-MODE

NORMAL

OFFSET

0.00000

OUT2

CALC

+0A1 +1A2

AVE

512

MEA-MODE

NORMAL

OFFSET

0.00000

01/02/18
17:50:42

CAM1

PROG

P – 00

LIMIT
AREA

OUTPUT

CALIB

OPTION

A1 2
A2 2

Area Calculation

The measured values from the two memory areas are used for calculation processing.

Setting Range

Select the coefficient from the following.
+1, +1/2, 0, –1/2, and –1

Examples of Area Calculation

By multiplying the measured values with the coefficient selected, automatic size calcu-
lation will be obtained. Set the coefficient as explained below to obtain the desired
output value.

No Calculation is Performed

A1

A2

+1

0

Obtaining the Outer Diameter from Two
Measuring Heads

Set AREA1 for DIA in measuring head 1
and AREA2 for DIA in measuring head 2.

A1

A2

+1/2

+1/2