5-5

Chapter 5 Function Settings

5

Output Settings (Page 5-29)

Item

Default

Area calculation (CALC)

OUT1: +1A1+0A2
OUT2: +0A1+1A2

Averaging number (AVE)

512

Measuring mode (MEA-MODE)

Normal

Offset

Threshold

Reference
value

0.00000

-99.99995 to +99.99995mm

+30.00000

0.00000

1000

μ

m/V

OFF

OFF, ON

+10.5V, Hold, 0V

0.4, 0.8, 1.6, 3.3, 6.6, 13.3, 26.6ms

OFF, 0.4, 0.8, 1.6, 3.3, 6.6, 13.3, 26.6ms

+10.5V

0.4ms

N.O.

OFF

Possible setting range

+0, +1, +1/2, -1, -1/2

Scaling at 10 V
(A-OUT+10)
Scaling at –10 V
(A-OUT-10)

Analog output setting: Analog update mode (A-SET)

Analog output setting: Output
waiting voltage (A-CONT)

Comparator output setting: Strobe
output time (STOBE-T)

Comparator output setting: Output
logic (OUT-SET)

Comparator output setting:
Off-delay time (OFF-DLY)

Scaling (A-SCALE)

1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1024,
2048, 4096

1, 2, 5, 10, 20, 50, 100, 200, 500, 1000, 2000,
5000, 10000

μ

m/V

Normally open (N.O.)
Normally closed (N.C.)

Normal
Peak hold (P-HOLD)
Bottom hold (B-HOLD)
Peak-to-peak hold (D-HOLD)
Average hold (AV-HOLD)
Automatic peak hold (A-P-HOLD)
Automatic bottom hold (A-B-HOLD)
Automatic peak-to-peak hold (A-D-HOLD)
Sample hold 1 (S-HOLD1)
Sample hold 2 (S-HOLD2)
Self-timing hold (SELF-T)
Self-timing period: 1 to 9999 ms
(By default set to 100 ms)

Option Settings (Page 5-55)

mm(mm),

μ

m(um), UNIT1(inch), UNIT2(mil)

mm: 0.00001, 0.00002, 0.00005,

0.0001, 0.0002, 0.001,
0.01, 0.1

Item

Default

Tolerance mode (LIMITS)

DEV

Timing mode (T-MODE)

ASYNC

Unit (D-UNIT)

mm

Minimum display unit (D-RES)

0.00005

I/O mode

SUB

Possible setting range

Reference value (DEV) or threshold (TOL)
Synchronous (SYNC) or asynchronous (ASYNC)

SUB mode (SUB), BCD mode (BCD)

Trend graph mode
(GRAPH-T)

Statistical processing
mode (STATS)
Group processing (GROUP)
Application mode (APP-MODE)

1m

1m

OFF
OFF
OFF
OFF

OUT1

OUT1

OUT2

OUT2

1m, 10m, 30m, 1H, 2H, 6H, 12H, 24H

1m, 10m, 30m, 1H, 2H, 6H, 12H, 24H

OFF, EXT, 2 to 9999999

OFF, EXT, 2 to 9999999

OFF, 2 to 255
OFF, DRILL, DUAL

Items in parentheses indicate what displayed on the LCD monitor.