Auto Peak Hold

• Auto peak hold:

The maximum value measured by the LS-7600 Series in
continuous measurement operation is displayed and output.

• Auto bottom hold:

The minimum value measured by the LS-7600 Series in
continuous measurement operation is displayed and output.

• Auto peak-to-peak hold: The maximum-to-minimum value measured by the LS-7600

Series in continuous measurement operation is displayed
and output .

Auto peak hold measured value

Internal
measured value

Judgment

Judgment

Measured value

t

RESET

processing

ON

OFF

Timing input

Waiting for judgment

(---------- displayed)

Measured value

ON

OFF

RESET input

ON

OFF

Comparator output

ON

OFF

RS-232C output

Judgment awaiting output

(Comparator waiting output)

• Comparator output turns ON according to the measured value.
• In the above chart, the ON status of each output means that NPN open collector output is ON, provided

that it is normally open type. If it is normally closed type, the signal will be inverted.

• The ON status of each input means that the input is short-circuited to the COM terminal.
• RS-232C output is ON in synchronization with timing input if the D-SEND item as an environment setting is

set to S1 or S2 only. Refer to Data Transmission Mode on page 6-9 for environment settings in detail.

• For strobe output in detail, refer to Strobe Output Time on page 5-47.
• For BCD output in detail, refer to BCD Output on pages 7-6 and 7-9.
• If timing input is ON during reset processing, the LCD monitor will display the result waiting status “---.-----.”

• If RESET input is ON while timing input is ON, awaiting the result of meas-

urement, the LCD monitor will display the result waiting status “---.-----“ until
the timing input is turned OFF.

• Timing input and reset input can be under RS-232C control. Refer to page

8-11 for details.

• If a workpiece is missing and there is a period without the internal measured

value obtained, the LCD monitor will display the result waiting status “---.-----
.” The LS-7600 Series will start measurement with the previous auto peak
value maintained when the internal measured value is obtained.

Tips

Advertising