Abort – Measurement Computing Analyzer488 User Manual

Page 111

Advertising
background image

Section 4

Serial Controller

4.17

ABORT

The ABORT command causes the Interface Clear (IFC) bus management line to

be asserted for at least 500 microseconds. By asserting IFC, the Analyzer488 regains
control of the bus even if one of the devices has locked it up during a data transfer.
ABORT

forces all IEEE 488 bus device interfaces into a quiescent idle state.

This command does not have a query option.

TYPE

High Level Controller command

SYNTAX

ABORT

RESPONSE

None

MODE

High Level Controller

BUS STATES

IFC, *IFC

QUERY

None

RESPONSE

EXAMPLES

PRINT#1,"ABORT"

pulse IFC line