Serial Controller

4.79

CONDITION

DESCRIPTION

RANGE

LAST TRIGGER LOC

Last Trigger Location

0 to 32767 *

LAST LOC WRITTEN

Last Location Written

0 to 32767 *

PRE TRIG COUNT

Pretrigger Count

0 to 99,999,999

PRE AVAILABLE

Pretrigger Recorded

0 to 32676

POST COUNT

Post Count

0 to 99,999,999

POST TRIG AVAILABLE

Post Trigger Recorded

0 to 32767

FIRST SEQ AVAILABLE

First

Location

Recorded

0 to 32767 *

TOTAL COUNT

Total Count

0 to 99,999,999

TOTAL AVAILABLE

Total Recorded

0 to 32767

* Returns 65535 if invalid

For example:

LAST TRIG LOC 14251 LAST LOC WRITTEN

31362 PRE TRIG COUNT 00043234 PRE AVAILABLE
30234 POST COUNT 07287434 POST TRIG AVAILABLE
26234 FIRST SEQ AVAILABLE 30437 TOTAL COUNT
00030437 TOTAL AVAILABLE 30437

STATUS 5

Returns information about the most recent recording sequence.
The response is the same as for STATUS 4, except that only
numbers are returned.

For example:

14251 31362

00043234 30243

07287434

26234

30437

00030437 30437