Section 4

Serial Controller

4.43

LOCAL

The LOCAL command causes the Analyzer488 to unassert the Remote Enable

line (REN). This causes devices on the bus to return to manual operation. If optional
bus addresses are specified, bus devices at those addresses are placed in the local
mode by the Go To Local (GTL) bus command. If addresses are specified, the state of
the Remote Enable line is not affected.

This command does not have a query option.

TYPE

High Level Controller command

SYNTAX

LOCAL [addr[,addr

...]]

addr

is an IEEE 488 bus device address.

RESPONSE

None

MODE

High Level Controller

BUS STATES

*REN (without addresses specified)
ATN•UNL, MTA, LAG,GTL (with addresses specified)

QUERY

None

RESPONSE

EXAMPLE

PRINT#1,"LOCAL"

Unassert the REN Line

PRINT#1,"LOCAL 12,16"

Send Go To Local to devices 12
and 16